PLC based control box for incinerator

i.   Circular Mild Steel / Stainless steel with minimum thickness
3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning.
ii. Proper port for taking exhaust gases sample to monitor emission levels as per international standards provided with a cover to be opened and closed when needed without affecting the function of chimney.
iii. Chimney should have height of at-least 15 meters from ground
level. incinerating waste
small scale incinerator
portable waste incinerator
10.     Electrical Control
i. PLC based control box with hinged sealed door, pre-installed control circuitry should be rugged enough to withstand the temperature effect of the incinerator.
ii. It should house the ignition burner time, feed interval timer, shutdown timer post combustion chamber temperature controller, control for burner, blower fans and gas washer.
iii. Digital display of temperature and set timing parameters.

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HOSPITAL WASTE INCINERATOR incineration Secondary Chamberincineration Secondary Chamber

According  to   the   European Waste   Incineration Directive, incineration Secondary Chambermust be designed to ensure that the flue gases reach a temperature of at least 1100 °C for 2 seconds in order to ensure proper breakdown of toxic organic substances.
ii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in Secondary combustion chamber furthermore air regulation and distribution will be automatic and electronically controlled.
iii. Chamber should have electrically operated natural gas burner.
5. Burners
i. Primary  and  Secondary  chamber  with  electrically  operated suitable for natural gas operation.
ii.  Regulated automatically for controlling of temperature inside
chambers.
iii. Automatic closing of burners if primary door chamber is not properly closed or opened during time of operation.
iv. Electrical safety to prevent startup of burner unless its shutter is fully opened, and closure of burner shutter when burner is switched off.
6. Waste Feeding System
i.   Automatic loading system to minimize user intervention. ii.  Auto opening and closing of primary chamber door.
iii. Hydraulic lifter with lifting capacity of minimum 500 kg load to lift waste trolley fixed by user for loading in incinerator.
7. Wet Scrubber / Gas Scrubber
i. Scrubber is air pollution control devices that use liquid to remove particulate matter or gasses from exhaust or flue gas steam. This atomized liquid (water) entrains particles and pollutant gases in order to effectively wash them out of the gas flow.
ii. Scrubber must be very multi-disciplinary with ability to remove solids, mist and gasses simultaneously while also providing cooling.
iii. Water saving system with re-circulating system and cooling tower.
8. Water Treatment System
i. Water treatment unit to treat the water used in Wet Scrubber before opening it into main drain.
ii.  System has settling tank with minimum thickness of 3mm

incinerator suppliers
small incinerators
portable incinerator

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Medical Waste Incineration and Medical Incinerators

1. Burning Capacity

i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading.

2. Construction

i.   Packaged type skid mounted dual chamber construction

ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint.

iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between

220C250 mm.

iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1.

v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55

60 oC even after continuous operation of 12 hours.

3. Primary Chamber

i. Chamber be designed with capacity to load 100kg medical waste with volume at least 1.2m3 or more, chamber must have separate door for loading of waste and for removal of ash using manual ash removing tool.

ii. Pyrolytic burning mechanism with burning temperature not below than 900 oC.

iii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in primary combustion chamber furthermore air  regulation and distribution will be automatic and electronically controlled.

iv.  Chamber should have electrically operated natural gas burner.


Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
animal incinerators
waste incinerators
hospital incinerators

Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower

 

Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower

Incinerator Items/Model

HICLOVER TS10(PLC)

 

Burn Rate (Average)

10-20 kg/hour

Feed Capacity(Average)

20kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

3.0Kw

Burner Type

Italy Brand

Oil Consumption (kg/hour)

6

N.Gas Consumption (m3n/hour)

***

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

System Testing Model

Yes

Time Setting

Yes

Progress Display Bar

LCD Display

Oil Tank

200L

Oil Tank Stand

Yes

Liquid level Display

Yes

Feeding Door

30x30cm

Chimney

3Meter

Chimney Type

Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

1800kg

External Dimensions

140x90x120cm(Incinerator Mainbody)

1st. Chamber Composition Hot Face

Thickness: ≥115 mm

55% of Al203

1750°C Grade

2nd. Chamber Composition Hot Face

Thickness: ≥115 mm

75% of Al203

1790°C Grade

Chamber Cold Face Material

High Rate Refractory Ceramic Fiber

Other Parts Hot Face Refractory

Heavy Duty with steel fiber

Burner operation

Automatic On/Off

Dry Scrubber

None

Wet Scrubber

Including

Top Loading Door

Optional

Paint for outside face

250°C Grade

Sealing Material

Refractory Ceramic Fiber

Upgrade Containerized Mobile Type

Optional

CE Certificate

CE(2006/42/EC,2014/30/EU

ISO Certificate

ISO9001:2015

High-tech Enterprise Certificate

Yes

     

 

 

 
 
 
 

 
 

 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      

2023-06-04

Industrial hazardous and nonhazardous waste and medical infectious waste

Industrial hazardous and nonhazardous waste and medical infectious waste
 

Incinerator Items/Model HICLOVER TS500(PLC) HICLOVER TS300(PLC)
Burn Rate (Average) 500-600 kg/hour 300-500 kg/hour
Feed Capacity(Average) 600kg/feeding 400kg/feeding
Control Mode PLC Automatic PLC Automatic
Primary Combustion Chamber 3000Liters(3.0m3) 2000Liters(2.0m3)
Internal Dimensions 2100x1200x1200mm 1700x1200x1000mm
Secondary Chamber 1500Liters(1.5m3) 1000Liters(1.0m3)
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual

 

Type of industries: Food processing units, beverages, Milk processing plants.
Incineration per day requirement: 300 to 500 Kg per hour capacity.
Loading: Automated continuous conveyor loading system.
No. of chambers: primary, Secondary and Tertiary chambers are required.
Treatment of gasses: scrubbing preferably dry type.
Water treatment: In case if you supply system with wet scrubbing unit.

Plc integration of all Temp, pressure, flu gas and residence time.
Heat recovery system/ or provision for future requirements.

 
 
 

 
 

laboratory incinerator
incineration of waste
smart ash incinerator

 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-10

industrial waste incinerator

Items/Model TS2000 (Top Feeding)
Principle Waste Incineration Treatment
Burn Rate Average 500-600kg/hour
Feed Capacity Average 4500kg/feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 7700Liter (7.7m3)
Internal Dimensions 5000*1400*1100 mm
Secondary Chamber 4000Liter (4.0m3)
Feed Mode Manual/Forklift/Crane

 

Description

Brand

Model

Fuel Type

Waste Incinerator

HICLOVER

TS2000

Oil/Gas

*Primary combustion chamber *Secondary combustion chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc

 

mobile Incinerator
hospital waste incineration
small medical waste incinerator
disposal of hazardous waste incinerator

 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-10


Vertical closed incinerator combustion chamber

Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, 
protective clothing and infectious and harm venereal hospital bed supplies, general wastes.
 
Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC)
Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour
Feed Capacity(Average) 480kg/feeding 800kg/feeding
Control Mode PLC Automatic PLC Automatic
Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3)
Internal Dimensions 220x110x100cm 257x147x108cm
Secondary Chamber 1200L 1500L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
 
Burning temperature First combustion chamber: 800- 900 ℃ ; Secondary combustion chamber:2000℃
Flue gas residence time≥1s
FURNACE BODY TYPE
Vertical closed furnace combustion chamber
BURNING CAPACITY 10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg
IGNITION MANNER
automatic
FUEL TYPE
0# or-20# diesel or natural gas
FEEDING MODE
Solid waste manual feeding
TAKE ASH MANNER
manual
FURNACE INNER PRESSURE adopt negative pressure design, no back-fire,―3~―10mmH2O
DESIGN HEAT VALUE waste mix 2000kcal/kg  ~5000kcal/kg,0# diesel 20000kcal/kg
FLUE GAS TREATMENT
Gasification combustion chamber(first combustion chamber) +
MANNER
blower + mixed combustion chamber+ high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan +
independent chimney.
Furnace body type Vertical closed furnace combustion chamber
Burning capacity 10-20kg/time (daily burn 3-6times, each time consume about 1
hour) total daily waste capacity 120 kg
Ignition manner automatic
Fuel type 0# or-20# diesel or natural gas
BURNING TEMPERATURE First    combustion    chamber:    800-900   ℃ ; –800℃–1000℃
Secondary combustion chamber:2000℃–1000℃-1300℃
Feeding mode Solid waste manual feeding
Take ash manner manual
Furnace inner pressure adopt negative pressure design, no back-fire,―3~―10mmH2O
Design heat value waste mix 2000kcal/kg  ~5000kcal/kg,0# diesel 20000kcal/kg
Flue gas treatment Gasification combustion chamber(first combustion chamber) +
manner blower + mixed combustion chamber+ high temperature secondary  combustion  chamber  +  flue  gas  purification room (calcium hydroxide filter brick) +exhaust fan + independent

 
 

 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-10

Waste Incinerator Capacity average 30-50 kgs per hour

Waste Incinerator Capacity average 30-50 kgs per hour
 

Model

YD-30C

Main Product List

 

Primary Combustion Chamber

 

 

Secondary Combustion Chamber

 

 

Mix-Combustion Chamber

 

 

Smoke Filter Chamber

 

 

Incinerator Control Case

(PLC Auto Type)

 

 

Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)

 

 

Italy oil burner: 02 sets

 

 

Oil Tank: 200Liters

 

 

Optional: Mobile Trailer for Incinerator

 
 
 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-10

Waste Incinerator HICLOVER TS100

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney 
*Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc

Waste Incinerator

HICLOVER

TS100

Burn Rate (Average) 100-150 kg/hour
Feed Capacity(Average) 200kg/feeding
Control Mode PLC Automatic
Primary Combustion Chamber 1200Liters(1.2m3)
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes
Feed Mode Manual

 
HICLOVER TS100(PLC)

 
 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-10

Incinerator Items/Model HICLOVER TS20(PLC)

Main Product List per 01 set
Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters 
*(upgrade to Stainless Steel, free cost)
Italy oil burner: 02 units
Oil Tank (if oil fuel): 200Liters

Incinerator Items/Model HICLOVER TS20(PLC)
Burn Rate (Average) 20-30 kg/hour
Feed Capacity(Average) 40kg/feeding
Control Mode PLC Automatic
Primary Combustion Chamber 210L
Internal Dimensions 65x65x50cm

 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-09


HICLOVER TS300(PLC) PLC Automatic Waste Incinerator

Default: Side Feeding Door
Optional: Front/Top Feeding Door, 
Wet scrubber

Incinerator Items/Model

HICLOVER TS300(PLC)

 

Burn Rate (Average)

300 kg/hour

Feed Capacity(Average)

400kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

2000Liters(2.0m3)

Internal Dimensions

1700x1200x1000mm

Secondary Chamber

1000Liters(1.0m3)

 
 
 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-09

INDUSTRIAL WASTE INCINERATORS FOR ALL SITES

 
 

Picture

 

Feeding Door Location

Top/Side Loading

Burn Rate (up to)

200-300 kg/hour

Control Mode

PLC Automatic

Primary Combustion Chamber

2000L(2.0M3)

Primary Combustion Chamber Internal Dimensions

2000x1200x850mm

Secondary Combustion Chamber

1000L(1.0m3)

Feed Mode

Manual/forklift/crane

***forklift/crane supply by local

 
 
We are particularly interested in your range of mobile incinerators and would appreciate it if you could provide us with a detailed quote that includes the cost of the unit, delivery, and installation. We would also like to know more about the features and specifications of your incinerators, as well as any warranty or maintenance options that may be available

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-09
 

CONTAINERIZED INCINERATOR ELECTRIC POWER SUPPLY: (GHANI 220V-50HZ-3PH, AMAL 220V-60HZ-3PH, RAS LANUF 380V_400V – 50HZ- 3PH, TIBISTI 220V-60HZ-3PH, EN-NAGA 220V- 50/60HZ- 3PH).GENERAL : A CONTAINERIZED INCINERATOR WITH DESIGHN SUITABLE FOR USE IN REMOTE AREAS SPECIFICALLY OIL AND GAS INDUSTRY.INCINERATOR UNIT SHOULD BE ABLE TO HANDLE COMMON WASTE WITH ABILITY TO ACCEPT SMALL AMOUNTS OF MEDICAL WASTE, BURNING RATE 300 KG/DAY WITH A CAPACITY TO OPERATE 8-16 HRS/DAY.PRIMARY CHAMBER SHOULD OPERATE AT 1200C WITH MINIMMUM OF 2 SEC RESIDENCE TIME. CONTAINER: SHAL BE FITTED WITH CHECKER PLATE FLOORING, FLOURESCENT LIGHTING, COMPLETE ELECTRICAL AND SAFTEY EQUIPMENT. A MANUFACTURER/ SUPPLIER MUST BE FOLLOWING FOR EACH UNIT: SPARE PARTS FOR ONE YEAR, INSTALLATION AND COMMISSIONING, ASUITABLE “1500-3000 L DIESEL TANK, INSTALLATION COMMISSIONING SPARE PARTS IF ANY, SHOULD BE INCLUDED AS PART OF THE PACKAGE, SEMI AUTOMATIC WASTE AND ASH HANDLING, AUTOMATIC TEMPERATURE CONTROL ON/OFF OPERATION. PLC BASED CONTROL PANEL, DIGITAL TEMPERATURE CONTROL. AUDIO VISUAL ALARM SYSTEM FOR BURNER LOCKOUT AND OVERLOAD FAULT, PRIMERY AND SECONDARY CHAMBER TEMPERATURE CONTROLLERS/INDICATORS, AUTO CONTRLOS, ELECTRICAL CONTROL SWICHES PUSH BUTTONS RELAYS, CONTACTORS, THERMOCOUPLES, BAURNER SEQUENCE CONTROLLERS, EMERGENCY STOP, TIMERS AND ALARMS. INCINERATOR CONSTRUCTION: COMBINED RECTANGULAR PRIMARY AND SECODNDARY CHAMBER CASING, CONSTRUCTED FORM A MINIMUM 6 MM MILD STEEL PLATE (BRACED AND STIFFENED EXTERNALLY) WITH A 10 MM MILD STEEL FRONT PLATE ALL WELDED TO A MILD STEEL BOX SECTION BASE frame. INTERNALLY THE CASING FORMING THE PRIMARY AND SECONDARY CHAMBERS SHALL BE LINED WITH GOOD QUALITY REFRACTORY AND FIREBRICK SUITABLE FOR TEMPERATURES UP TO 1400£°C, BACKED BY THERMAL INSULATION TO GIVE A COMBINED THICKNESS OF 225 MM. THE INCINERATOR SHALL BE PAINTED EXTERNALLY WITH TWO COATS OF HEAT-RESISTING PAINT. BURNERS: THE. PRIMARY CHAMBER SHALL BE FITTED WITH A SET OF TEMPERATURE/TIMER-CONTROLLED IGNITION BIIMERS. THE SECONDARY CHAMBER SHALL BE FITTED WITH A TEL OF TEMPERATURE-CONTROLLED BURNERS WHICH FIRE AUTOMATICALLY WHEN THE CHAMBER TEMPCFAT£«M IS BELOW 1050£°C. THE BURNERS SHALL BE DIESET OIL-FIRED PACKAGED TYPE AND INCLUDE AN ELECTRIC MOTOR, CONTROL BOX, FLAME FAILURE DEVICE, DIRECT DRIVE FAN, AIR REGULATION DAMPER, IGNITION TRANSFORMER, IGNITION ELECTRODE AND COMBUSTION HEAD. GRATE: TP PROCESS THE BURNING WASTE AND ASH THROUGH THE MAIM COMBMTION CHAMBER, A CAST IRON GRATE SHALL BE PROVIDED. THE GRATE SHALL BE CONSTRUCTED WITH HEAVY-DUTY CAST IRON SECTIONS SUPPORTED ON A CAST IRON FRAME. ASH TROLLEYS SHALL BE PROVIDED WITH THE SYSTEM WHERE SOLID ITEMS REMAIN ON THE GRATE. AIR SUPPLY: AIR FOR THE PRIMARY CHAMBER AND SECONDARY CHAMBERS SHALL BE VIA DIRECT DRIVE CENTRIFUGAL FANS. COATROL PANEL: THE CONTROL PANEL SHALL BE MOUNTED ON THE CONTAINER WALL AND BE EASLLY ACCESSIBLE AT ALL TIMES. IT SHALL BE SEALED TO IP 65 STANDARD AND HOUSE THE PLC, PRIMARY AND SECONDARY CHAMBER TEMPERATURE CONTROLLERS. MOTOR STARTERS OR RELAYS FOR FANS, BURNERS AND RAM LOADET, FUSES AND CONNECTION TERMINAL. MOUNTED ON THE PANEL DOOR THERE SHALL BE A PANEL DOOR ISOLATES, PRIMARY AND SECONDARY CHAMBER TEMPERATURE INDICATORS, MOTOR RUNNING LIGHTS, BURNER FIRING AND LOCKOUT LIGHTS, OVERLOAD FAULT, SHUTDOWN/RUN SWITCH AND EMERGENCY STOP. PRE-WIRING AND PRE-PIPING ALL WIRING BETWEEN TIRE CONTROL PANEL, BURNERS, MOTORS, FURNACE DOOR LOCK AND THERMOCOUPLE SHALL BE SECURED TO A WORK-FITTED GALVANIZED. CABLE TRAY. ALL WIRING BETWEEN THE BURNERS SHALL BE WOTK-FITTED AND TERMINATE IN THE CONTROL PANEL. ALL PIPING BETWEEN THE BARRIERS SHALL BE Work-FITTED AND TEMIINATE WITH a SINGLE THREADED CONNECTION AVAILABLE For CONNECTION TO THE ONSITE FUEL SUPPLY. CHIMNEY: THE STACK HEIGHT SHALL BE BETWEEN 6 METERS MINIMUM TO 10 METERS MAXIMUM AND COMPRISE OF A STANDARD CIRCULAR MILD STEEL CHIMNEY THAT MEETS TO BS4076 STANDARDS, MANUFACTURED IN FLANGED SECTIONS, MOUNTED ON TOP OF THE SECONDARY CHAMBER. INTERNALLY, THE CHIMNEY SHALL BE LINED WITH REFRACTORY CONCRETE SECURED TO THE STEELWORK BY STAINLESS STEEL CROOK ANCHORS. EXTERNALLY, THE SHELL SHALL BE THOROUGHLY PREPARED AND PAINTED WITH TWO COATS OF HEAT- RESISTING PAINT. CONTAINER: THE CONTAINER SHALL BE OF A STANDARD HIGH CUBE ISO TYPE, SUITABLE IN SIXÆ FOR INCINERATOR AND EQUIPMENT. CONSTRUCTION SHALL BE A STEEL FRAME, CONTAIPER CONNERS, AND PANEL WALLS, MODIFIED WITH A CONNECTION POINT FOR ELECTTICITY AND FUEL SUPPLY. STANDARD CONTAINER DOORS SHALL BE FITTED D ONE END, WITH DOUBLE DOORS FOR ACCESS AND DE-ASHING FITTED TO ONE SIDE AND A SINGLE PETAORNEL DOOR FITTED TO THE REAR. ALL DOORS SHALL BE SEALED BY RUBBER SEALS. WHERE THE CHIMNEY PASSES THROUGH THE ROOF A WEATHERING-UP STAND AND CRAVAT SHALL BE FITTED. WHERE ANY INSTALLATION BREAKS THE CONSTRUCIION, THE CONTAINER WILL BE REINFORCED. ALL WIRING WITHIN THC CONTAINER WILT BE A HEAVY-DUTY STEEL WIRE REINF0RCCD WIHI ARMORD CABLE. A SAFETY LADDER AND HAND RAILING SHALL BE PROVIDED FOR ACCESS TO THE CHIMNEY. DATA: PTIMARY CHAMBER VOLUME- 308(M3), BURNING CAPACITY 300 (KG/DAY), TYPE OF WASTE: GENERAL WASTE DENDITY 100-120 KGS/M3, PRIMERY CHAMBER TEMPERATURE: 850-900 (£°C), SECONDARY CHAMBER TEMPRATURE: 1100/1200 (£°C) , SECONDARY CHMBER RESIDENCE TIME 2.0 (SEC) , REFRACTORY/INSTULATION THICKMESS 225(MM), REFRACTORY WITHSTAND TEMPRATURE 1400 (£°C)- RAM LOADER CAPACITY 0.5M3, OPERATIONAL CUCLES PER DAY (HOOURS) 8-16 HRS, NU,BER OF PRIMARY BURNERS & RATING 2@200KW, NUMBER OF SECONDARY BURNERS & RATING 2@300KW, COMPRESSOR RATING 0.5 M3/MIN @9BAR, DIESEL TANK SIZE 1500-3000 I-MEDIUM DENSITY POLY ETHYLENE WITH LEVEL INDICATOR, INTERCONNECTING PIPWORK TO INCINERATOR, FREE FALL FIRE VALVE, ISOLATING VALVES FILTER, FUEL TYPE DIESEL, REFRACTORY MATERIAL FIRE BRICK/REFRACTORY @ 42% ALUMINA, INSULLATION CALCIUM SILICATE/ROCKWOOL.

Medical waste incinerator Burning Rate 100kg/hr

Subject Medical waste incinerator
Day Capacity 1000kg
Waste Type Medical waste
 

 

Description

Brand

Model

Fuel Type

Medical Incinerator

HICLOVER

TS100

Diesel Oil/Natural Gas

*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature Thermometer *CE/ISO certification,etc

 
 

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100-150 kg/hour

Feed Capacity(Average)

200kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-08

Waste Incinerator YD500(PLC) and YD600(PLC)

Thermocouples (S type)
Thermocouples Tube(Corundum )
PLC Recording Function
5mm Steel shell
Window on feed door

 
 

Incinerator Items/Model

HICLOVER YD500(PLC)

HICLOVER YD600(PLC)

Burn Rate (Average)

500-600 kg/hour

600-800 kg/hour

Feed Capacity(Average)

800kg/feeding

11000kg/feeding

Control Mode

PLC Automatic

PLC Automatic

Primary Combustion Chamber

4000L(4.0M3)

5500L(5.5M3)

Internal Dimensions

257x147x108cm

300x147x125cm

Secondary Chamber

1500L

1500L

Smoke Filter Chamber

Yes

Yes

Feed Mode

Manual

Manual

Voltage

220V

220V

Power

4.8Kw

6.0Kw

Burner Type

Italy Brand

Italy Brand

 
 

 
 
 
 

Nanjing Clover Medical Technology Co.,Ltd.
Ecolead Technology(Nanjing) Co.,Ltd.
Mobile: +86-13813931455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected] 
Email:     [email protected]      
2023-04-08

medical wasteincinerator manufacturers

Model

TS10 PLC

Main Product List per 01 set

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Smoke Filter Chamber

 

Incinerator PLC Control Case

 

Chimney:6.0Meters

*(upgrade to Stainless Steel, free cost)

 

Italy oil/gas burner: 02 units

 

Oil Tank (if oil fuel): 200Liters

incineration of solid waste
pathological waste incinerator
incineration of medical waste
medical incinerator manufacturers

Incinerator Items/Model

HICLOVER TS10(PLC)

 

Burn Rate (Average)

10-20 kg/hour

Feed Capacity(Average)

20kg/feeding

Control Mode

PLC Automatic

Primary Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual


Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

incinerator for hospital

1, Using fever of gasifying unites burning technology. It applied to burn various 
kinds of medical waste, such as syringes, infusion set, disposable dressing, and also 
small animal, some city waste, like paper, tree leaves.
2, Closed vacuum-wide operation, applicable to treat infectious medical waste and to prevent secondary pollution.
3, Whole design, easy to transfer to different place.
4, Combustion burner from China or Italy.
garbage incinerators
container Incinerator
small incinerator
incinerators for sale
china waste incinerator

Incinerator Items/Model

HICLOVER

TS30(PLC)

HICLOVER TS50(PLC)

HICLOVER TS100(PLC)

HICLOVER TS150(PLC)

Picture

 

 

 

 

Feeding Door Location

Top

Top

Top

Top

Burn Rate (Average)

100-150 kg/hour

100-150 kg/hour

100-150 kg/hour

100-150 kg/hour

Spontaneous Combustion Model

20-150kgs/Hour

20-150kgs/Hour

20-150kgs/Hour

20-150kgs/Hour

Feed Capacity(Average)

80kg/feeding

140kg/feeding

200kg/feeding

280kg/feeding

Control Mode

PLC Automatic

PLC Automatic

PLC Automatic

PLC Automatic

Primary Combustion Chamber

405L(0.4M3)

700L(0.7M3)

1050L(1.0M3)

1400Liters(1.4m3)

Internal Dimensions

900x750x600mm

1250x800x700mm

1300x900x900mm

1400x1000x1000mm

Secondary Chamber

200L(0.2m3)

350L(0.35m3)

500L(0.5m3)

700Liters(0.7m3)

Smoke Filter Chamber

Yes

Yes

Yes

Yes

Feed Mode

Manual/forklift/crane

Manual/forklift/crane

Manual/forklift/crane

Manual/forklift/crane

Voltage

220V 

220V 

220V 

220V 

Power

0.5Kw

0.7Kw

0.9Kw

1.5Kw

Burner Type

Italy Brand

Italy Brand

Italy Brand

Italy Brand

Oil Consumption (kg/hour)

Max.15.0

Max.15.0

Max.15.0

Max.15.0